Ventobacco Curing Controllers

VK 981 (pg. 4/5)

· To operate AUTOMATICALLY you select No. 6 (AUTO) on the SELECTOR.
AUTO Light is on.
The Curing will automatically advance, starting from the ambient D.B. temperature in the barn changing Automatically the Curing phases following exactly the curing program. The rate of Temperature Increase, DT, DB and WB temperature limits where the operator wishes to stop, as well as the duration of each stop, can be reprogrammed from the operator (if he wishes so) with the use of "SETTINGS" and +, - buttons. The Computer's detailed operation mode is described in the VENTOBACCO VK 981 OPERATOR'S MANUAL.

More details on VK 981 Curing Computer

· By pressing SELECT & START buttons together, Operator can see where the "Floating" D.B. is set automatically by the control at that precise moment
If he wants to increase or decrease the "floating" temperature, he can do so by pressing button + or - while he keeps pressed SELECT & START buttons.
· Sensors calibration : factory calibrated. Calibration can be checked or changed (if a sensor is changed) from control's menu.
· Differential : (Hysterisis) : Can be changed from Control's menu.

Electrical & sensor's connection