VCU®
is our latest Compact Complete Curing Unit equipped
with Computer Curing Controller, specially designed
to fit almost all traditional tobacco barns and the Vencon
designed farmer made brick barns.
VCU® is
an autonomous all galvanised and insulated compact group with
totally stainless steel combustion chamber and heat exchanger,
high efficiency fan with IP55 motor, automatic Diesel or Gas
burner, automatic Fresh Air Damper ready to be mounted on
existing barn's back wall.
VCU ®
is automatically controlling barn's air recirculation, burner's
and fresh air intake damper's operation, rate of temperature
increase, dT, humidity decrease and several other factors
securing a perfect cure.
Available in 5 sizes,from 400 to 3.500 Kgs dry leaf per
cure.
Designed to secure perfect and clean
Curing directing the combustion gases and combustion by-products
outside the barn so there is no contact with the Curing tobacco
to prevent the formation of Tobacco Specific Nitrosamines
(TSNAs) and secure clean and well cured dry tobacco.
Ventobacco®
Heat exchanger Curing Units (VCU) dramatically
reduce the contents of TSNAs in the cured tobacco compared
with any of the direct fired Units.
Ventobacco Heat Exchangers
for Fuel (Diesel) oil, LPGas or Natural gas firing are all
built in high quality stainless steel material with large
Heat Exchange Surface, to secure a trouble free operation
for decades.
An automatic burner fires in the combustion chamber. The hot
gases are then directed through a heat exchanger with flattened
smoke tubes to the chimney to be exhausted outside to the
atmosphere.
The recirculating air stream travelling around it, (combustion
chamber and flattened tubes) is heated, cooling down at the
same time the heat exchanger.
Heat exchanger's combustion chamber and flattened tubes are
designed for the highest possible efficiency to secure as
low fuel consumption as possible.
Fuel consumption with Ventobacco
®
Heat exchangers (VCU) is the same or even lower than
with direct fired Curing units.
HOT WATER VCU.
Hot water is circulating inside a specially built heating
coil.
Hot water produced in a boiler is recirculating in the heating
coil through a system of pipeline, pump and 3 way valve
controlled from VCU's Curing Computer VK 981.One Hot water
boiler can feed up to 7 (seven) VCUs with hot water.
Boilers are built with either :
- Fuel
(Diesel) oil, LPG, or Natural gas burners
- Solid
fuel (wood or coal) burning
[Intro]
[Facts] [VCU
model 2K] [Efficiency-emmisions ]
[Installation
Recomendation]
|