For your information: How burner's Gas valves operate

When the two Gas valves (Operating & Safety) take power from Burner's Control box, to open,
a) Safety valve opens immediately
b) Operating valve opens gradually according to valve's Start Adjustment which determines how wide and how fast will be valve's Initial opening to give smooth Gas Ignition.
You can readjust START if necessary, having in mind that too small or too wide START Adjustment may cause burner's "lock out".
Note: To adjust correctly START screw you need to connect a water gauge to the Gas head (operating valve's) pressure measuring point (30) so you can see the water in the gauge rising smoothly without "locks"
when Gas valves open.
The time required to open totally the operating valve also depends on SPEED Adjustment (factory precalibrated and sealed).
(For detailed information on Burner's adjustments ask for our detailed technical manual).